X-Ray Sub Systems

Polaris® 360 shown with SC-500 Full Featured Controller

Polaris® 360 Power Supply Specifications

  • Input Voltage: 180-264VAC, 47-63 Hertz, power factor corrected – input to ≥ 0.98
  • Input Current: < 25 amps
  • Output Voltage: Load: ±0.05% of rated output voltage for a full load change Line: ±0.05% of rated output voltage over specified input voltage range (360kV @ up to 9kW – limited by x-ray tube specification)
  • Reproducibility: + 0.01%, assuming constant temperature
  • Stability: ≤0.1% per 8 hours, after 1 hour warm up
  • Temperature Coefficient (drift): < 50ppm/°C
  • Emission Current: Load: ±0.05% of rated output current for a change from 30% to 100% of rated output voltage

Filament:

  • Output: 0-6 amps at a compliance of 10Vdc, maximum
  • Dual Focal Spot: Small and large, selectable via interface signal
  • Configuration: DC filament drive. Closed loop emission control regulates filament setting to  provide desired X-ray tube emission current

Control Interface:

  • Remote Interface: Analog, USB, Ethernet and RS-232 & RS-485
  • Control Software: Any of Kimtron’s controllers, A VB GUI is provided for RS-232/USB – the Ethernet interface has an embedded applet for control
  • Operating Temperature: 0°C to +50°C
  • Storage Temperature: -40°C to +85°C
  • Humidity: 20% to 85% RH, non-condensing

Interface Connectors:

  • Digital—Ethernet, RS-232 and USB
  • Analog—25 pin connector
  • Output Connector: Industry standard R-24
  • Cooling: Filtered forced air

Polaris® SC-500 Controller Specifications

The SC-500controller is not only the most advance controller in Kimtron’s line of x-ray controllers, but is also the most advanced x-ray controller in the NDT market.

In keeping with Kimtron’s philosophy of being “incredibly easy to do business with”, Kimtron designed the SC-500 with the end-user in mind; all components used in this unit are readily available on an off-the-shelf basis – no proprietary hardware is used enabling the end-user to fully support the unit in-house, if they so choose.

Features / Benefits

  • Based upon high-quality, globally supported off-the-shelf components
  • Robust, industrial-grade graphical user interface
  • Long-life LED lamps – no bulbs to burn out or change
  • Available in either stand-alone enclosure, rack-mountable 6 U panel or pedestal stand
  • Software upgrades performed via flash memory – no need to send unit back to OEM
  • Remote communications – system can be diagnosed via dial-up
  • On-board auxiliary tube-temperature sensor
  • Modular and easy-to-troubleshoot I/O interface panel (all schematics included)
  • Flags and faults presented in easily understood text format – no numbers to decipher
  • Able to address infinite number of x-ray tube-types
  • Event log maintains most recent 750 events
  • Warm-up log maintains history of most recent 250 warm-up cycles
  • Displays demand as well as actual feedback values (kV & mA)
  • Ability to store up to 2500 techniques
  • 3 or 4 digit resolution (based upon customer request at time of order)
  • Ability to address up to three separate x-ray tube parameters simultaneously
  • Auto Watt
  • Auto warm-up
  • “Tube-safe®” feature shuts down system when preset number of tube arcs are sensed

Operator selectable inputs include:

  • kV control via graphical sliding scale or emulated keypad entry
  • mA control via graphical sliding scale or emulated keypad entry
  • Timer with graphical “time remaining” display
  • Filament select (Large / Small)
  • Warm-up modes, long & short
  • “X-rays on” push button
  • “X-rays off” push button
  • Text-based fault code display
  • Three position Key switch; “Off”, “Stand-by” & “Run”

Safety devices include:

  • Amber “pre-warn” lamp
  • Red “X-rays on” lamp
  • White “Power on” lamp
  • Green “safety” lamp